Pre drill holes on the ridges.
Corrugated metal roofing installation details.
When a metal roofing sheet must be installed on a curved roof screws should be installed at every overlapping rib at the sheet ends to resist the natural ten dency of the metal to spring back.
Valley and snow design.
Install the roofing screws vertically along each rib in the panel.
Start at the highest point and the furthest point from the trash container and take off all the old.
Installing corrugated roofing 1.
Corrugated metal roofing generally comes in sheets that are 3x6 feet in size 18 square feet.
Installation of residential corrugated metal roof systems usvi ra3 march 2018 page 2 of 9 construction mitigation g uidance this section provides the following.
Depending on the area of the roof you can use different sized panels.
Allow for a minimum of 18.
Be sure the larger edge is laid so that the small edge of the next panel will overlap it.
It is recommended that 7 8 corrugated panels have a minimum slope requirement of 3 12 on all structures.
Also for exposed fastener panels wall panels tiles soffit fascia copping.
Multiply those numbers and then double the result for the square footage of your roof.
For added protection from rain and snow it is recommended to use rubberized ice and water shield on eaves valleys and areas of roof penetrations.
Without getting up on the roof itself you can get the measurements simply by measuring the.
Work at a comfortable steady pace trying not to rip up or carry off too much old roofing at once.
Cut the panels to the desired length.
When a metal roofing sheet must be installed on a curved roof screws should be installed at every overlapping rib at the sheet ends to resist the natural tendency of the metal to spring back.
The standard fastening pattern is permitted over the rest of the sheet.
When installing the metal panels shown in this booklet over a curved arch the minimum.
Measure the length of the roof and the breadth of one side.
Corrugated metal roof installation instructions step 1.
Some panels have pre drilled holes.
You can either buy.
The standard fastening pattern is permitted over the rest of the sheet.
Before you start to install corrugated metal roofing you need to figure out how much you need.
Examples of corrugated metal roof assembly problems that were observed after the 2017 hurricanes wind design criteria for roof systems roof system installation details.
Metal roofing specifications cad pdf drawings testing bim.
Align the first metal roofing panel so that it overlaps the edging by 1 2 to 3 4 of an inch and is square to the roof line.
Most panels come up to 32 feet 9 8 m in length.